![Digital controller for Medium and Low Temperature ventilated applications with a - XR75CX](/image/21/XR75CX.gif)
Technical Data : Digital controller for Medium and Low Temperature ventilated applications with a - XR75CX
Features | |
---|---|
Display | 3 digits, d.p., - |
Power supply | 24, 110, 230Vac |
Probe inputs | |
Thermostat | NTC / Pt1000 |
Defrost | NTC / Pt1000 |
Condenser | NTC / Pt1000 |
Digital inputs | |
Alarm, AUX, start defrost, door switch, pressure switch, probe | configurable |
Alarm, AUX, start defrost, door switch, pressure switch | configurable |
Relay outputs | |
Compressor | 8A, 16A optional |
Defrost | 8A |
Fans | 5A |
Light or alarm | 8A |
Other Outputs | |
Hot Key output | present |
Remote display output | X-REP optional |
Serial output | TTL / RS485 optional |
Other | |
Buzzer | optional |
Real time clock | optional |
Measurement | |
Measurement range | probe dependent |
Accuracy | Better than 1% of full scale |
Generals | |
Housing | Self extinguishing ABS |
Front protection | IP65 |
Display type | red LED (13mm high) with icons blue LED optional |
Data Storage | EEPROM memory |
Operating temperature | 0°÷60°C 32°÷140°F |
Storage temperature | -25°÷60°C -13°÷140°F |
Relative humidity | 20÷85% |
Resolution | 0.1°C or 1°F |
Connection | Screw-terminal block <2.5mm² |